Edaochi Medical
WhatsApp

Cath Lab & Hemodynamics

17 products available — PTCA balloons, guidewires, radial and femoral introducers, hemostasis valves, manifolds and cath-lab consumables.

Respiratory Supplies IV Infusion ICU & Procedures Nursing & Diagnostics Collection & Lab Radiology & Contrast Media Cath Lab & Hemodynamics
Catéter Balón PTCA — Semicompliante y No Compliante — PTCA Balloon Catheter — Semi-Compliant & Non-Compliant SKU XY-PTBCath Lab & Hemodynamics
Guía PTCA 0,014" — Cinco Cargas de Punta — PTCA Guidewire 0.014" — Five Tip Loads SKU XY-PTWCath Lab & Hemodynamics
Set de Válvula Hemostática en Y — Rosca, Push-Pull y Click — Y Hemostasis Valve Set — Twist, Push-Pull & Click SKU XY-HVSCath Lab & Hemodynamics
Dispositivo de Inflado de Balón — 30 y 40 bar, con Manómetro — Balloon Inflation Device — 30 & 40 bar, with Gauge SKU XY-INFCath Lab & Hemodynamics
Catéter de Angiografía Diagnóstica — 14 Curvas, 4/5/6 F — Diagnostic Angiographic Catheter — 14 Shapes, 4/5/6 F SKU XY-ANCCath Lab & Hemodynamics
Set Introductor Radial — 4 a 8 F, con Aguja y Guía — Transradial Introducer Set — 4 to 8 F, with Needle & Wire SKU XY-RISCath Lab & Hemodynamics
Set Introductor Femoral — 4 a 10 F, Tres Construcciones — Femoral Introducer Set — 4 to 10 F, Three Builds SKU XY-FISCath Lab & Hemodynamics
Manifold de Hemodinamia — 1 a 3 Llaves, 250 y 500 PSI — Cath-Lab Manifold — 1 to 3 Stopcocks, 250 & 500 PSI SKU XY-CLMCath Lab & Hemodynamics
Guía ERCP — 0,025" a 0,035", hasta 450 cm — ERCP Guidewire — 0.025" to 0.035", up to 450 cm SKU XY-EGWCath Lab & Hemodynamics
Guía con Recubrimiento PTFE — 0,021" a 0,038", punta J o recta — PTFE-Coated Guidewire — 0.021" to 0.038", J or Straight Tip SKU XY-PGWCath Lab & Hemodynamics
Guía Hidrofílica — Alma de Nitinol, 0,032" a 0,038" — Hydrophilic Guidewire — Nitinol Core, 0.032" to 0.038" SKU XY-HGWCath Lab & Hemodynamics
Guías de Nitinol y Acero — 0,018" a 0,050", 10 a 300 cm — Nitinol & Stainless Guidewires — 0.018" to 0.050", 10 to 300 cm SKU XY-NGWCath Lab & Hemodynamics
Jeringa de Control de Dosis — 10, 12 y 20 ml — Dose-Control Syringe — 10, 12 & 20 ml SKU XY-DCSCath Lab & Hemodynamics
Jeringas de Pistón de Color — 3 a 20 ml, 6 Colores — Colour-Piston Syringes — 3 to 20 ml, 6 Colours SKU XY-CPSCath Lab & Hemodynamics
Agujas Introductoras de Punción — 18G y 20G, Tipo Y — Introducer Puncture Needles — 18G & 20G, Y-Type SKU XY-INNCath Lab & Hemodynamics
Banda de Compresión Hemostática — Radial y de Balón — Hemostatic Compression Band — Radial & Balloon Type SKU XY-CBDCath Lab & Hemodynamics
Línea de Alta Presión para Inyección — 500 y 1200 PSI — High-Pressure Injection Line — 500 & 1200 PSI SKU XY-HPLCath Lab & Hemodynamics

Buying guide — Cath Lab & Hemodynamics

Cath-lab consumables are bought as a system, not as loose parts: the introducer fixes the French size, the catheter must pass through that introducer, the wire must pass through that catheter, and the hemostasis valve must seal around that wire. One mis-ordered link leaves the whole box unusable. That is why this category is organised by procedure step — access, navigation, treatment, injection — and every page carries its compatibility table. We supply PTCA balloons, guidewires in five tip loads, radial and femoral introducer sets, hemostasis valves, inflation devices and manifolds to distributors serving hemodynamics and interventional units.

What to verify before buying

  • The compatibility chain: introducer French ≥ catheter French; 0.014" wire for PTCA — verify the whole chain before ordering
  • Balloon NP and RBP — semi-compliant and non-compliant are not interchangeable
  • Injection-circuit pressure: 250 or 500 PSI manifolds, 300 / 500 / 1200 PSI lines by use
  • Radial vs femoral access — each route has its own introducer; today's mix leans radial
  • EO sterilisation and ISO 13485 lot traceability — specification and compatibility only, no clinical claims

The compatibility chain: French sizes and inches

Every measurement in interventional work nests inside the next one, and purchases fail when one chart is read in isolation. The sequence never changes:

LinkMeasureMust fit
Introducer (sheath)French (4–10 F)The access artery and the catheter passing through it
Guide / diagnostic catheterFrench (4–6 F)The introducer's inner lumen
GuidewireInches (0.014"–0.038")The catheter's lumen
PTCA balloonDiameter mm × length mmThe 0.014" wire and the guide catheter
Hemostasis valvePer wireThe whole system, sealing around the wire

When quoting, send the full combination your unit runs — introducer, catheter, wire and balloon — and we verify it as a system. Five minutes of checking that prevents this category's most common return.

Buying by procedure step

Access. Radial introducer sets (4–8 F, with puncture needle and short wire) and femoral sets (4–10 F, three build types). Radial dominates today's mix; femoral remains mandatory at large sizes.

Navigation. 0.014" PTCA wires in five tip loads — 0.7 g to 12 g — plus PTFE and hydrophilic diagnostic wires. Tip load is not a preference: every operator works a ladder of loads and the box should reflect it.

Treatment. Semi-compliant PTCA balloons for predilatation, non-compliant for high-pressure postdilatation. NP and RBP printed on every page; they do not substitute for each other.

Injection and control. Manifolds with 1 to 3 stopcocks (250 / 500 PSI), inflation devices with gauge (30 / 40 bar), Y hemostasis valve sets with torquer and inserter included, and high-pressure lines up to 1200 PSI.

OEM components from this same family — stopcocks, connectors, torquers in bulk for set assemblers — live on the stopcock & connector OEM line, with component MOQs and packaging.

Frequently asked questions — Cath Lab & Hemodynamics

Can I order the complete system in one quote?

Yes, and it is the recommended way: send the introducer, catheter, wire and balloon your unit runs and we verify the full compatibility chain before manufacturing. Mixed orders consolidate into one shipment.

Do balloons and wires need special registration?

They are high-class medical devices in most markets; the finished-device registration is handled by the distributor in the destination market using our documentation — technical file, manufacturer ISO 13485 and per-batch sterilisation. Confirm local classification before importing.

Do you manufacture under private label?

Yes. Pouch and print under your brand from per-reference quantities. Bulk components for assemblers (stopcocks, torquers, connectors) sit on the OEM line with component terms.

¿Necesitas insumos para tu clínica u hospital?

Need medical supplies for your clinic or hospital?

Cotización por WhatsApp en menos de 24 horas. Envío mundial — Latinoamérica, EE.UU., Europa, Medio Oriente y más.

Escríbenos ahora / Contact Us