Edaochi Medical
WhatsApp
Home / Catalog / Cath Lab & Hemodynamics / Transradial Introducer Set — 4 to 8 F, with Needle & Wire
Transradial Introducer Set — 4 to 8 F, with Needle & Wire — XY-RIS imagen 1
Cath Lab & Hemodynamics

Transradial Introducer Set — 4 to 8 F, with Needle & Wire

SKU: XY-RIS | Set Introductor Radial — 4 a 8 F, con Aguja y Guía

In stock — Worldwide shipping

Complete set for radial artery access, the route that now dominates coronary intervention. Each set carries the sheath with its dilator, the puncture needle and the short access wire — everything that happens between palpating the pulse and the first catheter going in. Three builds: Twist, with threaded valve, in 4–8 F and 7, 11 and 16 cm lengths, with a 0.018" × 65 cm angled nitinol wire and 20 G puncture cannula; Click, with single-gesture valve, in 4–7 F with a straight 0.021"/0.025" × 45 cm wire; and Click II in 5–7 F and 7, 10 and 11 cm, with a 0.018" × 45 cm wire and 21 G needle. The radial artery punishes spasm: the sheath-dilator transition is continuous and the surface treated to cut entry and withdrawal friction. State build, size and length when quoting; a typical unit's mix loads on 5 and 6 F.

Technical Specifications

Product typeTransradial introducer set (sheath + dilator + needle + wire + syringe)
Twist buildThreaded valve · 4–8 F · 7/11/16 cm · nitinol 0.018" × 65 cm angled wire · 20 G × 3.2 cm cannula
Click buildSingle-gesture valve · 4–7 F · 7/11/16 cm · straight 0.021"/0.025" × 45 cm wire
Click II build5–7 F · 7/10/11 cm · 0.018" × 45 cm straight wire · 21 G × 4.0 cm needle
SheathContinuous transition with dilator; low-friction surface
Access wireKink-resistant nitinol or steel, by build
SterilisationEthylene oxide (EO), individual pack
UseSingle-use / Disposable
Quality systemManufactured under ISO 13485, per-batch traceability
CodeXY-RIS

Clinical Uses

  • Radial artery access in coronary angiography and intervention
  • Distal radial access with short lengths
  • Same-day discharge programmes via the radial route
  • Replenishment by the unit's preferred build

Radial set builds

The three builds differ in the sheath valve and the included access wire. Size follows the catheter that will pass; length is operator preference.

BuildSizesLengthsIncluded wirePuncture
Twist4–8 F7 · 11 · 16 cmNitinol 0.018" × 65 cm, angled20 G × 3.2 cm cannula
Click4–7 F7 · 11 · 16 cmSteel 0.021"/0.025" × 45 cm, straightPer set
Click II5–7 F7 · 10 · 11 cm0.018" × 45 cm, straight21 G × 4.0 cm needle

A coronary unit's real mix loads on 5 and 6 F. 7–8 F is ordered for complex procedures; confirm your exact combination when quoting.

Frequently Asked Questions — Transradial Introducer Set — 4 to 8 F, with Needle & Wire

Which build should I order?

By valve and by wire. Twist gives progressive closure and ships the 65 cm angled nitinol wire — the most ordered standard. Click seals in one gesture with a straight steel wire. Click II is the compact variant with a fine 21 G needle, favoured for distal radial. In doubt, a mixed box of Twist and Click II answers the question in a month of real use.

Why does the sheath-dilator transition matter in radial?

Because the radial artery spasms. Any step between dilator and sheath scrapes the intima on entry and hurts on withdrawal; the continuous transition and low-friction surface exist for exactly that moment. It is the difference operators notice in the first box.

Does the set include everything for access?

Yes: sheath with dilator, puncture needle or cannula, short access wire and syringe, in one sterile pack. The diagnostic catheter or wire that follows is ordered separately — see the angiographic catheter in this category.

What is the minimum order?

Quoted by build with the size × length mix consolidated. Send your estimated split (the usual loads on 5–6 F × 11 cm) and monthly volume. Documentation: technical file, ISO 13485, per-batch sterilisation.

Request a Sample

Samples available for evaluation. Basic items: free sample. Higher-value items: a sample fee may apply. Shipping not included.

Request Sample

Full Description — Transradial Introducer Set — 4 to 8 F, with Needle & Wire

Everything between pulse and catheter

Sheath and dilator, puncture needle or cannula, short access wire, syringe — one sterile pack covers the access step entirely. The diagnostic catheter that follows is ordered separately.

Why the transition matters more in radial

The radial artery spasms. Any step between dilator and sheath scrapes the intima going in and hurts coming out; the continuous transition and low-friction surface exist for exactly that moment.

Choosing the build

Twist brings progressive closure and the 65 cm angled nitinol wire — the standard order. Click seals in one gesture with a straight steel wire. Click II is the compact variant with a fine 21 G needle, favoured for distal radial. A mixed box answers the preference question in a month.

What to confirm before ordering

- Build and the size × length mix (5–6 F × 11 cm is the usual centre) - Distal radial programmes: Click II short lengths - Monthly volume for tiered pricing

Related Products

¿Necesitas insumos para tu clínica u hospital?

Need medical supplies for your clinic or hospital?

Cotización por WhatsApp en menos de 24 horas. Envío mundial — Latinoamérica, EE.UU., Europa, Medio Oriente y más.

Escríbenos ahora / Contact Us