High-Pressure Injection Line — 500 & 1200 PSI
SKU: XY-HPL | Línea de Alta Presión para Inyección — 500 y 1200 PSI
The high-pressure line joins manifold, syringe or injector to the catheter, and its pressure class is not a safety margin but a different construction. The 500 PSI class, in clear DEHP-free high-durometer PVC, covers the room's manual work: injection with the dose-control syringe, and monitoring lines where the stiff wall keeps the pressure trace faithful. The 1200 PSI class, reinforced, is the only correct one when a power injector sits in the circuit — DSA and automated runs. Both in lengths of 25, 50, 75, 100, 120, 150 and 180 cm, with a female Luer at one end and a male rotator at the other: the rotator stops the line twisting as it is threaded, and a twisted line under pressure is a kink waiting to form. This is the sterile procedure reference; the same programme as a bulk component for assemblers lives on the OEM line, and the 300 PSI contrast lines with check valves in the radiology category.
Technical Specifications
Clinical Uses
- Manifold-to-catheter connection in manual injection (500 PSI)
- Pressure monitoring lines with high-durometer wall
- Power injector circuits (1200 PSI)
- Sterile cath-lab replenishment
Pressure-class selection
The class is chosen by the most demanding element in the circuit, and classes never substitute upward: a 500 PSI line on a power injector is this family's serious purchasing error.
| Class | Construction | For which circuit | Lengths |
|---|---|---|---|
| 500 PSI | Clear DEHP-free PVC, high durometer | Manual syringe injection · monitoring lines | 25–180 cm |
| 1200 PSI | Reinforced | Power injector: DSA, automated runs | 25–180 cm |
The 300 PSI contrast lines (straight, Y and coiled, with check valves) are in the radiology category; the bulk component for assemblers on the OEM line.
Frequently Asked Questions — High-Pressure Injection Line — 500 & 1200 PSI
Can I use the 500 PSI line with a power injector?
No. A power injector generates peaks far above 500 PSI, and the class is not a prudent margin but a different construction: wall, reinforcement, connectors. If an injector is in the circuit, the line is 1200 PSI without exception — this family's serious purchasing error, and why the table says it twice.
Why high durometer for monitoring lines?
A soft wall expands with every pressure wave and damps the curve: the transducer reads the tube's elasticity instead of the artery. The 500 class's high durometer keeps the signal faithful from catheter to transducer — the same principle as the ICU 500 PSI line, here in room format.
What does the rotator end add?
Threading a fixed Luer makes the line turn with the nut and end up twisted; under pressure that torsion is a kink waiting to form. The rotator end decouples thread from line: the connection tightens and the tube stays at rest. A minor detail until a run is lost to a kink.
How does this differ from the OEM page and the radiology lines?
Three formats of the same programme. This is the sterile room reference, procedure-ready. The OEM one is the non-sterile bulk component for assemblers, with component MOQs. The radiology ones are the 300 PSI contrast lines with check valves for CT/MRI injector sets. Choose by use; the three are quoted separately.
Request a Sample
Samples available for evaluation. Basic items: free sample. Higher-value items: a sample fee may apply. Shipping not included.
Full Description — High-Pressure Injection Line — 500 & 1200 PSI
Class is construction, not margin
Wall, reinforcement and connectors differ between classes. If a power injector sits anywhere in the circuit, the line is 1200 PSI — no exceptions, no averaging.
Why monitoring wants the stiff wall
A soft wall expands with each pressure wave and damps the trace: the transducer reads the tubing's elasticity instead of the artery. High durometer keeps the signal faithful from catheter to transducer.
The rotator detail
Threading a fixed Luer twists the line; under pressure that torsion becomes a kink. The rotator decouples nut from tube — tighten the connection, the line stays at rest.
Three formats of one programme
Sterile room reference here; bulk OEM component for assemblers; 300 PSI check-valve contrast lines in radiology. Choose by use.
What to confirm before ordering
- Class split by circuit (any injector → 1200 PSI) - Length mix - Sterile boxes or OEM bulk