Edaochi Medical
WhatsApp
Home / Catalog / Respiratory Supplies / Standard Disposable Mechanical Ventilation Breathing Circuit
Standard Disposable Mechanical Ventilation Breathing Circuit — XY466V2 imagen 1
🫁 Respiratory Supplies

Standard Disposable Mechanical Ventilation Breathing Circuit

SKU: XY466V2 | Circuito de Ventilación Mecánica Desechable — Modelo Estándar

In stock — Worldwide shipping
$0.90–$2.80por unidadMOQ: Desde 1 caja (10 uds.)

Precio referencial. Consulte con nuestro equipo para cotización exacta.

Disposable dual-limb breathing circuit for ICU mechanical ventilation. 22 mm ISO corrugated tubing with separate inspiratory and expiratory limbs and a water trap integrated on the expiratory limb to prevent condensate build-up. Compatible with Puritan Bennett, Hamilton, Maquet, Mindray and similar ventilators. Medical PVC, latex-free, EO sterile.

Technical Specifications

ConfigurationDual-limb (inspiratory + expiratory)
Tube diameter22 mm ISO
Water trapIntegrated on the expiratory limb
MaterialMedical PVC, latex-free
SterilisationEthylene oxide (EO)
CodeXY466V2

Clinical Uses

  • Controlled and assisted mechanical ventilation in the adult ICU
  • CPAP and BiPAP with a closed circuit
  • Prolonged ventilatory support on the ward

Frequently Asked Questions — Standard Disposable Mechanical Ventilation Breathing Circuit

What is the difference between the XY466V2 and the XY467 circuit?

Both are ICU mechanical-ventilation circuits. The XY466V2 is the standard model with a water trap integrated on the expiratory limb; the XY467 is the basic model without a water trap. For prolonged procedures the XY466V2 is recommended.

How often is the XY466V2 ventilation circuit changed?

International guidance recommends changing every 7 days in the absence of visible contamination. With active respiratory infection or contaminated secretions, change more often per clinical judgement.

Is the XY466V2 compatible with active humidifiers?

Yes. It can be used with heated-wire active humidifiers (e.g. Fisher & Paykel MR850 or similar) instead of a passive HME filter. For active humidification, a heated-wire circuit is recommended to minimise condensation.

Request a Sample

Samples available for evaluation. Basic items: free sample. Higher-value items: a sample fee may apply. Shipping not included.

Request Sample

Full Description — Standard Disposable Mechanical Ventilation Breathing Circuit

Edaochi Medical's standard ICU ventilation circuit (SKU XY466V2) is the dual-limb workhorse for adult intensive care — built around a water trap so condensate never reaches the patient.

Dual-limb with a water trap

Separate inspiratory and expiratory limbs reduce dead space, and the water trap on the expiratory limb collects condensate that would otherwise pool and run back toward the airway during long ventilation. 22 mm ISO corrugated tubing fits Puritan Bennett, Hamilton, Maquet, Mindray and similar ventilators. Compared with the trap-free XY467 circuit, this is the choice for prolonged support.

Humidification and change interval

Use with a passive HME filter or a heated-wire active humidifier. Change every 7 days absent visible soiling — see our ventilator circuit change frequency & VAP guide and the breathing circuits guide.

Buying wholesale

Factory-direct, latex-free, EO sterile. Specify limb length, humidification type and packaging; OEM and samples available. Box price and MOQ quote on WhatsApp within 24 h.

Related Products

¿Necesitas insumos para tu clínica u hospital?

Need medical supplies for your clinic or hospital?

Cotización por WhatsApp en menos de 24 horas. Envío mundial — Latinoamérica, EE.UU., Europa, Medio Oriente y más.

Escríbenos ahora / Contact Us