Edaochi Medical
WhatsApp
Home / Catalog / ICU & Procedures / Hemodialysis Bloodline Set: Arterial and Venous
Hemodialysis Bloodline Set: Arterial and Venous — XY-BLS imagen 1
ICU & Procedures

Hemodialysis Bloodline Set: Arterial and Venous

SKU: XY-BLS | Línea de Sangre para Hemodiálisis: Set Arterial y Venoso

In stock — Worldwide shipping
$1.60–$2.40USDper set (arterial + venous)MOQ: No minimum order

Reference price for the complete set. What moves it is the pump-segment diameter, whether the transducer protector is built in, the packaging format (single line or both together) and OEM customisation. At container volume and on the fastest-moving configurations the price falls below this range. There is no minimum order: any quantity is produced, with a different operating mode depending on volume.

Bloodline set for the extracorporeal hemodialysis circuit in adult patients. It consists of the arterial line, colour-coded red and the venous line, colour-coded blue. The arterial line carries the pump segment, the arterial chamber with pressure port, the heparin line, the sampling port, the recirculation connector and the priming line; the venous line carries the venous chamber with filter screen, the transducer protector, its own sampling port and its recirculation connector. The pump segment is made in two outer diameters, 12.1 mm and 9.75 mm and that is the first decision when specifying, because it is the part that has to seat in the machine's roller pump. Compatibility is broad: the set fits most hemodialysis machines on the market, with the exception of the Fresenius 5008 and 5008S and of certain proprietary-circuit machines. Packaging follows the market: single line for South America, where buying practice is by individual line and both lines packed together elsewhere. Medical PVC tubing. CE marked, ethylene oxide sterilised and manufactured in a class 100,000 (ISO Class 8) cleanroom or better. Single use. There is no minimum order: any quantity is produced, with a different operating mode depending on volume and shipping is normally by full container. Private label available for distributors and importers.

Technical Specifications

Product typeDisposable extracorporeal blood circuit (bloodline), arterial + venous set
PatientAdult (no paediatric or neonatal version is made)
Pump segmentTwo options: 12.1 mm OD (8.0 mm ID) or 9.75 mm OD, effective length 330 ± 20 mm
Main blood line4.4 mm ID × 6.8 mm OD
Auxiliary lines2.5 mm ID × 4.1 mm OD
Heparin line1.0 mm ID × 2.6 mm OD, effective length 530 ± 20 mm
Colour codingArterial red, venous blue, on connectors, clamps and caps
Arterial chamberBody and cap with pressure port, sampling port and recirculation connector
Venous chamberBody and cap with filter screen, sampling port and recirculation connector
Transducer protectorAvailable built in, specified to customer requirement
Priming lineIncluded on the arterial line for saline priming
ClampsColour-coded line clamps on both lines
CompatibilityMost machines on the market. NOT compatible with Fresenius 5008 / 5008S or with proprietary-circuit machines
MaterialMedical PVC
CertificationCE
ManufacturingClass 100,000 (ISO Class 8) cleanroom or better
SterilisationEthylene oxide (EO), sterile, single use
PackagingSingle line (South America) or both lines together (other markets)
UseSingle use / Disposable
Minimum orderNo MOQ, any quantity is produced; shipping is normally by full container
OEMPrivate label, configuration and packaging all customisable
CodeXY-BLS

Clinical Uses

  • Chronic hemodialysis in outpatient dialysis centres
  • Acute hemodialysis in ICU and critical care units
  • Per-session replacement of the extracorporeal blood circuit
  • Volume supply to distributors, importers and dialysis chains
  • OEM assembly under private label for nephrology catalogues

Set dimensions and effective lengths (adult)

The table a dialysis buyer needs before ordering and that almost nobody publishes. Lengths are effective, to a ±20 mm tolerance; the long run on each line is the one from patient to machine.

SegmentSize (ID × OD)Arterial line (red)Venous line (blue)
Pump segment8.0 × 12.1 mm · 9.75 mm OD330 mm
Main blood line4.4 × 6.8 mm1,580 · 830 · 580 · 330 mm1,780 · 430 · 430 mm
Auxiliary runs2.5 × 4.1 mm80 · 80 · 30 mm580 · 80 mm
Heparin line1.0 × 2.6 mm530 mm

Pump segment: choose 12.1 mm or 9.75 mm OD to match your machine's roller, it is the first specification to confirm and the one that causes most returns when ordered blind. The inner diameter of the 9.75 mm segment is confirmed at quotation. State as well whether you need the transducer protector built in and whether packaging is per individual line or with both lines together.

Frequently Asked Questions — Hemodialysis Bloodline Set: Arterial and Venous

Which hemodialysis machines is it compatible with?

Most machines currently on the market. The known exceptions are the Fresenius 5008 and 5008S and some proprietary-circuit machines that only accept their own manufacturer's consumable. If your machine fleet is mixed, send us the models when requesting a quote and we will confirm the fit before manufacturing, compatibility is decided at the pump segment, not across the rest of the circuit.

What sizes does the pump segment come in and which should I order?

Two outer diameters: 12.1 mm and 9.75 mm, both with an effective length of 330 ± 20 mm. The 12.1 mm has an 8.0 mm inner diameter. Which one applies is decided by your machine's roller, not by centre preference: a segment that does not seat will not pump and it is the specification error that generates most returns on this item. If you do not have the figure to hand, give us the machine make and model and we will settle it.

Does the set include a transducer protector?

It can. It is specified to customer requirement: some centres mandate it on the venous line under their infection-control protocol, others buy it separately. State it when requesting a quote and it is fitted at the factory in the configuration you order.

How is it packaged?

Both ways, depending on the market. In South America buying practice is by individual line, so the single line is packed there. In other markets the usual format is arterial and venous packed together. Tell us which you need, it is a packaging decision, not a product one and it changes nothing about the circuit specification.

Is there a paediatric or neonatal version?

No. We currently make the adult configuration only. If your demand is paediatric, tell us with an estimated volume and we will evaluate it, but today it is not a catalogue item.

What are the lengths of each run in the circuit?

They are all in the dimension table on this page, the figure you would normally have to email a manufacturer for. In short: the arterial line carries runs of 1,580, 830, 580 and 330 mm in the 4.4 × 6.8 mm main tubing, plus the 330 mm pump segment and the 530 mm heparin line; the venous line carries 1,780, 430 and 430 mm. All lengths are effective, to a ±20 mm tolerance.

How is it sterilised and how do I check it arrived sterile?

It is ethylene oxide (EO) sterilised and sealed in sterile packaging. On receipt, what matters is pack integrity: a seal that is open, punctured or damp voids sterility even if the product looks perfect. It is single use and cannot be resterilised, the circuit has been in contact with blood and there is no way to clean it internally.

How much does one patient consume per year and how do I size an order?

A chronic hemodialysis patient has around three sessions a week, roughly 150-160 a year and each session opens a fresh set. The base calculation for an order is patients x 156 x a wastage factor. This is what separates it from the catheter, which is placed once per patient and lasts weeks: the bloodline is the consumable that sets a dialysis centre reorder rhythm, which is why it is worth quoting on an annual horizon rather than order by order.

What regulatory documentation do you provide?

The product is CE marked. We provide the technical data sheet, instructions for use and the conformity documentation needed for device registration in the destination market and for public tender files. Finished-device registration is held by the distributor in their market; we supply the manufacturing file behind it.

What do you need in order to quote?

Four things: the pump-segment diameter (or, failing that, the make and model of your machines, which is more reliable), whether you need the transducer protector built in, the packaging format - single line or arterial + venous set - and the estimated quantity. That is enough to quote without further back and forth. If you want to evaluate first, ask for samples in the same message.

What is the minimum order?

There is none. We produce any quantity, the operating mode changes with the volume rather than the door being closed below a threshold, which is unusual in this category where bloodlines are normally quoted by the container. Shipping is normally by full container for established programmes; smaller quantities are handled differently and we will tell you how when you send the figure. On the fastest-moving configurations at container volume, the price sits below the range published on this page.

Do you offer private label for distributors?

Yes. We manufacture unbranded by default and the packaging carries the customer's brand. Set configuration, pump-segment diameter, inclusion of the transducer protector, packaging format and printing are all customisable. Send us your machine fleet and estimated monthly volume Send us the specification and we will come back with a box price; if you would rather see the product first, we will ship samples.

Request a Quote — Hemodialysis Bloodline Set: Arterial and Venous

Reply within 24 business hours with FOB/CIF price, MOQ and lead time. SKU XY-BLS is already attached to your request — just add the quantity.

We only use your details to reply to this enquiry.

Request a Sample

Samples available for evaluation. Basic items: free sample. Higher-value items: a sample fee may apply. Shipping not included.

Request Sample

Full Description — Hemodialysis Bloodline Set: Arterial and Venous

The hemodialysis bloodline is the circuit through which the patient's blood leaves the vascular access, passes through the dialyser and returns. It is a per-session consumable: a patient on chronic dialysis gets through roughly 156 sessions a year, each one opening a fresh set. That makes it a high-volume, tightly specified item, where a dimensional error is not discovered in the warehouse but at the machine, with the patient already connected.

What each line carries

The set is two colour-coded lines and they are not symmetrical:

  • Arterial line (red): the one that draws blood. It carries the pump segment, the run that seats in the peristaltic pump roller; the arterial chamber with its pressure port; the heparin line for continuous anticoagulation; the sampling port; the recirculation connector; and the priming line for flushing the circuit with saline before connecting the patient.
  • Venous line (blue): the one that returns blood. It carries the venous chamber with filter screen, which catches clots and traps air before return; the transducer protector; its own sampling port; and the recirculation connector.

The red/blue coding is on connectors, clamps and caps, not just the label: it is what stops the lines being reversed when the circuit is assembled in a hurry.

The dimension that decides the purchase: the pump segment

Of the whole circuit, the part that determines whether the set works is the pump segment. We make it in two outer diameters:

  • 12.1 mm OD (8.0 mm inner diameter)
  • 9.75 mm OD

Both with an effective length of 330 ± 20 mm. Which one applies is decided by the machine's roller rather than by the centre and it is the specification error that generates most returns on this item: a segment that does not seat in the pump head will not pump and the whole set is unusable even when the rest of the circuit is right. If you do not have the figure to hand, give us the machine make and model and we will settle it before manufacturing.

Compatibility: what fits and what does not

The set fits most hemodialysis machines on the market today. The exceptions we know of and that are worth stating up front:

  • Fresenius 5008 and 5008S: not compatible.
  • Proprietary-circuit machines: some manufacturers close the system so it only accepts their own consumable.

We would rather publish the exclusion list than a "universally compatible" claim that does not hold up afterwards. If your fleet is mixed, send us the models and we will confirm the fit machine by machine.

Dimensions of the rest of the circuit

The main blood tubing is 4.4 mm ID × 6.8 mm OD, auxiliary runs are 2.5 mm ID × 4.1 mm OD and the heparin line is 1.0 mm ID × 2.6 mm OD. The effective length of every run is in the table on this page, the figure you would normally email a manufacturer for and wait two days to get. All to a ±20 mm tolerance.

Packaging: South America buys differently

This is a real market difference and we handle it at the factory. In South America, buying practice is by individual line, so the single line is packed there. In other markets the usual format is arterial and venous packed together. It changes nothing in the circuit specification, only the format, but ordering the wrong format complicates the sale to the end customer, so it is worth settling on the first order.

Made-to-requirement configuration

The transducer protector is built in or not according to customer requirement: some centres mandate it on the venous line under their infection-control protocol, others buy it separately. The same applies to packaging format and branding. Tubing is medical PVC. The product is CE marked and manufactured in a class 100,000 (ISO Class 8) cleanroom or better, in the adult configuration, there is no paediatric or neonatal reference in the catalogue today.

No minimum order

There is no MOQ on this line. Any quantity is produced; what changes with volume is the operating mode, not whether the order is accepted. Established programmes ship by full container, and on the fastest-moving configurations the price sits below the range published on this page. For a category normally quoted by the container and closed below it, being able to start small is the difference between evaluating this line and not.

Related reference

Vascular access for the acute session is covered by the hemodialysis catheterization kit, in double lumen 8.0–12.0 Fr and triple lumen 11.5–12.0 Fr. Catheter and bloodline are the two references a nephrology distributor orders together.

Quoting

Tell us the pump-segment diameter (or the make and model of your machines), whether you need the transducer protector built in, the packaging format and your estimated monthly volume. Send us the specification and we will come back with a box price; if you would rather see the product first, we will ship samples.

*Please confirm product specifications, regulatory requirements and intended use with your local regulatory authority before purchase.*

Related Products

¿Necesitas insumos para tu clínica u hospital?

Need medical supplies for your clinic or hospital?

Cotización por WhatsApp en menos de 24 horas. Envío mundial — Latinoamérica, EE.UU., Europa, Medio Oriente y más.

Escríbenos ahora / Contact Us