Edaochi Medical
WhatsApp
Home / Catalog / OB/GYN / Uterine Stent Balloon — 9 Fr, Cavity-Shaped
Uterine Stent Balloon — 9 Fr, Cavity-Shaped — XY-USB imagen 1
OB/GYN

Uterine Stent Balloon — 9 Fr, Cavity-Shaped

SKU: XY-USB | Balón de Stent Uterino — 9 Fr, Conformado a Cavidad

In stock — Worldwide shipping

The uterine stent balloon is the family's third and smallest: after intrauterine surgery it keeps the cavity walls apart while they heal. Its shape is not spherical but cavity-conformed — roughly triangular, like the uterus itself — to bear evenly without pressure points. Fine 9 Fr body and two sizes (3 × 2.8 cm and 4 × 4.0 cm) covering usual anatomical variation. Working volume is deliberately small: the goal is gentle separating contact, not pressure — the opposite extreme from this category's postpartum balloon, and the reason none of the family's three balloons substitutes for another. A surgical hysteroscopy consumable, sized by procedures per month.

Technical Specifications

Product typeCavity-shaped uterine stent balloon
Size9 Fr
Sizes3 × 2.8 cm · 4 × 4.0 cm
ShapeConformed to the uterine cavity — even bearing, no pressure points
PrincipleGentle wall separation during healing — low volume, not pressure
SterilisationEthylene oxide (EO), individual pack
UseSingle-use / Disposable
Quality systemManufactured under ISO 13485, per-batch traceability
CodeXY-USB

Clinical Uses

  • Cavity maintenance after hysteroscopic surgery
  • Uterine wall separation during healing
  • Surgical hysteroscopy services
  • Two-size pair for anatomical variation

Frequently Asked Questions — Uterine Stent Balloon — 9 Fr, Cavity-Shaped

How does it differ from the postpartum balloon?

In everything but the organ. The postpartum fills the cavity to 500 ml to tamponade a haemorrhage with pressure; this one works with millilitres to keep the walls barely apart while healing. Confusing them on an order is the error this whole category's wording exists to prevent — 'uterine balloon' without a surname is ambiguous.

Why does the conformed shape matter?

A spherical balloon in a triangular cavity bears at three points and leaves the rest untouched. The conformed shape spreads bearing across the whole wall — even separation without pressure zones, which is exactly a healing stent's job.

Which size?

Both, in ratio: 3 × 2.8 cm covers the average cavity, 4 × 4.0 cm the broad one. The surgeon chooses at the moment by the cavity just operated — hence the correct purchase carries both on the tray.

How is the order sized?

By hysteroscopic procedures per month. Documentation: technical file, manufacturer ISO 13485 and per-batch sterilisation; destination registration by the distributor.

Request a Sample

Samples available for evaluation. Basic items: free sample. Higher-value items: a sample fee may apply. Shipping not included.

Request Sample

Full Description — Uterine Stent Balloon — 9 Fr, Cavity-Shaped

The smallest balloon with the gentlest job

Millilitres, not pressure: walls kept barely apart while they heal. The exact opposite of the 500 ml tamponade — and why "uterine balloon" without a surname is an ambiguous order line.

Shape is the spec

A sphere in a triangular cavity touches at three points. The conformed shape spreads contact across the whole wall — even separation, which is a healing stent's entire job.

Both sizes on the tray

The surgeon chooses per cavity, at the moment. 3 × 2.8 covers the average; 4 × 4.0 the broad. The correct purchase carries both.

What to confirm before ordering

- Hysteroscopic procedures per month - Size split (both, in ratio)

Related Products

¿Necesitas insumos para tu clínica u hospital?

Need medical supplies for your clinic or hospital?

Cotización por WhatsApp en menos de 24 horas. Envío mundial — Latinoamérica, EE.UU., Europa, Medio Oriente y más.

Escríbenos ahora / Contact Us